Leaving Cert Chemistry · Volumetric Analysis: Oxidation-ReductionRedox titrations and iron tablets

24 sections · 18 key terms · Syllabus 4.1.2, 4.1.6

Redox titrations

  • A redox titration finds the concentration of an oxidising or reducing agent by titrating it against a reducing or oxidising agent of known concentration.
  • The mole ratio used in the calculation comes from the balanced redox equation.
  • The apparatus and technique are the same as in “Acid–base titrations”: pipette, burette, conical flask and white tile, with rough and accurate titrations agreeing within 0.1 cm³.
  • The end point is shown either by the colour of one of the reagents themselves (self-indicating, as with potassium manganate(VII)) or by an indicator (starch in iodine–thiosulfate titrations).
  • The two redox titrations in the specification are potassium manganate(VII) with iron(II), and iodine with sodium thiosulfate.

Potassium manganate(VII)

  • Potassium manganate(VII), KMnO₄ (potassium permanganate), is a dark purple solid; its solution is an intense purple and it is a strong oxidising agent.
  • It is usually used at about 0.01–0.02 mol L⁻¹.
  • It is not a primary standard: it can't be obtained pure, and its solution slowly decomposes in light and in the presence of traces of organic matter, depositing brown MnO₂, so its concentration changes.
  • It is therefore standardised against ammonium iron(II) sulfate shortly before use.

Reaction with iron(II)

  • In acidic solution MnO₄⁻ is reduced to the almost colourless manganese(II) ion: MnO₄⁻(aq) + 8H⁺(aq) + 5e⁻ → Mn²⁺(aq) + 4H₂O(l), with manganese changing from +7 to +2.
  • Iron(II) is oxidised: Fe²⁺(aq) → Fe³⁺(aq) + e⁻.
  • Overall: MnO₄⁻(aq) + 5Fe²⁺(aq) + 8H⁺(aq) → Mn²⁺(aq) + 5Fe³⁺(aq) + 4H₂O(l), so MnO₄⁻ : Fe²⁺ = 1 : 5.
  • The Mn²⁺ ions produced catalyse the reaction (autocatalysis: a product of the reaction is its catalyst), so the first few drops are decolourised slowly and later drops almost at once.

End point and reading the burette

  • Potassium manganate(VII) is self-indicating, so no indicator is added.
  • The KMnO₄ goes in the burette; each drop is decolourised while Fe²⁺ remains in the flask.
  • The end point is the first permanent pale pink colour, produced by the first drop of excess MnO₄⁻.
  • The solution is so deeply coloured that the bottom of the meniscus can't be seen, so read the top of the meniscus, consistently for both readings.
  • Rinse the burette thoroughly after use, because permanganate leaves brown stains of MnO₂ on glass.

Acidifying the permanganate titration

  • Excess dilute sulfuric acid is added to the flask to supply the H⁺ ions needed for the reduction.
  • With too little acid, MnO₄⁻ is reduced only to manganese(IV) oxide, forming a brown precipitate: MnO₄⁻ + 2H₂O + 3e⁻ → MnO₂(s) + 4OH⁻, with manganese changing from +7 to +4.
  • With too little acid the ratio is no longer 1 : 5 and the end point can't be seen.
  • Hydrochloric acid is not used, because MnO₄⁻ oxidises Cl⁻ to chlorine, using up extra permanganate.
  • Nitric acid is not used, because it is itself an oxidising agent and would oxidise some of the Fe²⁺.

Ammonium iron(II) sulfate as the standard

  • Ammonium iron(II) sulfate hexahydrate, (NH₄)₂SO₄·FeSO₄·6H₂O, also written (NH₄)₂Fe(SO₄)₂·6H₂O, has M = 392 g mol⁻¹ and forms pale green crystals.
  • It is a double salt: ammonium sulfate and iron(II) sulfate crystallise together in a fixed ratio in one crystal.
  • Its standard solution is made up as in “Solutions and concentration”, with the crystals dissolved in deionised water and some dilute sulfuric acid added.
  • The acid stops Fe²⁺ being oxidised to Fe³⁺ by dissolved oxygen.

Why ammonium iron(II) sulfate is a primary standard

  • It can be obtained very pure.
  • It is stable in air: the solid is not oxidised by air, does not absorb water and does not lose its water of crystallisation.
  • It is soluble and has a high molar mass, so weighing errors are a small percentage of the mass weighed.
  • Iron(II) sulfate itself is not used: its crystals are oxidised by air to iron(III) and their water content varies, so a weighed mass does not correspond to a known amount of Fe²⁺.

Standardising potassium manganate(VII): procedure

  • Pipette 25.0 cm³ of the standard ammonium iron(II) sulfate solution into a conical flask.
  • Add about 20 cm³ of dilute sulfuric acid with a graduated cylinder; its volume does not need to be exact.
  • Titrate with the KMnO₄ solution from the burette, swirling, until one drop gives a permanent pale pink colour.
  • Repeat until two titres agree within 0.1 cm³.
  • Diagram pipette with its filler, labelled with the graduation mark at 25.0 cm³.
  • Diagram graduated cylinder marked in cm³, labelled with the scale used to measure the sulfuric acid.
  • Diagram burette of purple KMnO₄ above a conical flask on a white tile, labelled with the burette tap and the top of the meniscus.

Sample calculation: standardising potassium manganate(VII) (sample data)

  • Data: 25.0 cm³ of 0.0500 mol L⁻¹ ammonium iron(II) sulfate needs a mean titre of 24.4 cm³ of KMnO₄.
  • Moles Fe²⁺ = 0.0500 mol L⁻¹ × 0.0250 L = 1.25 × 10⁻³ mol.
  • Moles MnO₄⁻ = 1.25 × 10⁻³ mol ÷ 5 = 2.50 × 10⁻⁴ mol, since MnO₄⁻ : Fe²⁺ = 1 : 5.
  • Concentration of KMnO₄ = 2.50 × 10⁻⁴ mol ÷ 0.0244 L = 0.0102 mol L⁻¹.

Iodine and sodium thiosulfate: reagents

  • Sodium thiosulfate, Na₂S₂O₃·5H₂O (M = 248 g mol⁻¹), is a colourless crystalline solid and a reducing agent.
  • The thiosulfate ion, S₂O₃²⁻, is like a sulfate ion with one oxygen replaced by sulfur; “thio” means sulfur.
  • Sodium thiosulfate is not a primary standard: its crystals are efflorescent, losing water of crystallisation to the air, so their exact formula and the mass of thiosulfate are uncertain.
  • Its solution is therefore standardised against iodine made from a standard oxidising agent.
  • Iodine is not a primary standard either: it sublimes slowly at room temperature, so it cannot be weighed accurately, and it is almost insoluble in water.

Dissolving iodine and the titration reaction

  • Iodine is brought into solution with potassium iodide: I₂ + I⁻ ⇌ I₃⁻.
  • The tri-iodide ion is charged, so it dissolves in water; the solution behaves as a solution of iodine and is red-brown.
  • Titration reaction: I₂(aq) + 2S₂O₃²⁻(aq) → 2I⁻(aq) + S₄O₆²⁻(aq), so I₂ : S₂O₃²⁻ = 1 : 2.
  • Iodine is the oxidising agent; thiosulfate is the reducing agent and is oxidised to the tetrathionate ion, S₄O₆²⁻.
  • The iodine solution is pipetted into the conical flask and the thiosulfate is in the burette.

Colour change and the starch indicator

  • As thiosulfate is added, the red-brown iodine fades to yellow and then to pale yellow (straw-coloured).
  • At pale yellow, add a few drops of freshly made starch solution, which turns blue-black.
  • Add thiosulfate drop by drop until the blue-black colour just disappears, leaving a colourless solution: the end point.
  • Starch is added only near the end point, because with a lot of iodine present, iodine binds strongly to the starch and is released only slowly, so the colour change would be gradual and the end point inaccurate.
  • The pale yellow colour also shows that the end point is close.

Deionised water and uses of thiosulfate

  • Use deionised water throughout, not tap water: tap water contains dissolved chlorine from water treatment, which oxidises iodide to extra iodine (Cl₂ + 2I⁻ → 2Cl⁻ + I₂).
  • Sodium thiosulfate is used to remove excess chlorine from water, reducing it to harmless chloride ions.
  • Sodium thiosulfate is the “fixer” (“hypo”) in film photography.

Standardising sodium thiosulfate: procedure

  • Pipette 25.0 cm³ of standardised KMnO₄ solution into a conical flask and add about 20 cm³ of dilute sulfuric acid.
  • Add an excess of potassium iodide, as solution or solid: the purple colour disappears and red-brown iodine forms: 2MnO₄⁻ + 10I⁻ + 16H⁺ → 2Mn²⁺ + 5I₂ + 8H₂O.
  • Potassium iodide is in excess for two reasons: so that all the MnO₄⁻ reacts, producing a known amount of iodine; and so that the iodine stays in solution as I₃⁻.
  • Titrate the liberated iodine with the thiosulfate solution by the starch method described above.
  • Combined ratio: 2MnO₄⁻ → 5I₂ → 10S₂O₃²⁻, so MnO₄⁻ : S₂O₃²⁻ = 1 : 5.

Sample calculation: standardising sodium thiosulfate (sample data)

  • Data: 25.0 cm³ of 0.0200 mol L⁻¹ KMnO₄ liberates iodine that needs a mean titre of 25.3 cm³ of thiosulfate.
  • Moles MnO₄⁻ = 0.0200 mol L⁻¹ × 0.0250 L = 5.00 × 10⁻⁴ mol.
  • Moles I₂ = 5.00 × 10⁻⁴ mol × 5 ÷ 2 = 1.25 × 10⁻³ mol, since 2MnO₄⁻ gives 5I₂.
  • Moles S₂O₃²⁻ = 2 × 1.25 × 10⁻³ mol = 2.50 × 10⁻³ mol, since I₂ : S₂O₃²⁻ = 1 : 2.
  • Concentration of thiosulfate = 2.50 × 10⁻³ mol ÷ 0.0253 L = 0.0988 mol L⁻¹.

Terms about water and crystals

  • Efflorescent: a hydrated crystal that loses some of its water of crystallisation to the air on standing, e.g. sodium thiosulfate pentahydrate and washing soda (Na₂CO₃·10H₂O).
  • Hygroscopic: absorbs water vapour from the air without dissolving, e.g. concentrated sulfuric acid and silica gel.
  • Deliquescent: absorbs so much water from the air that it dissolves in it and forms a solution, e.g. sodium hydroxide pellets.
  • None of these substances can be a primary standard, because the mass weighed does not correspond to a known amount of substance.

Safety

  • Wear goggles: potassium manganate(VII) is an oxidising agent, is harmful, and stains skin and clothes.
  • Dilute sulfuric acid is an irritant; iodine solution stains and is harmful.
  • Use a pipette filler.

Aim, hypothesis and chemistry

  • Aim: to find the mass of iron in an iron tablet, and the percentage of elemental iron by mass in the tablet, by titration with a standard solution of potassium manganate(VII).
  • Iron tablets contain iron as iron(II), commonly as iron(II) sulfate (iron(II) fumarate and iron(II) gluconate are also used), and are prescribed to treat iron-deficiency anaemia.
  • The label usually gives the mass of the iron compound or of iron per tablet.
  • Equation: MnO₄⁻(aq) + 5Fe²⁺(aq) + 8H⁺(aq) → Mn²⁺(aq) + 5Fe³⁺(aq) + 4H₂O(l), so MnO₄⁻ : Fe²⁺ = 1 : 5.
  • The KMnO₄ solution is first standardised against ammonium iron(II) sulfate, just before use, as described in “Redox titrations”.
  • Hypothesis (example): the tablet contains the mass of iron stated on the label, within a few percent.

Making the tablet solution

  • Weigh five tablets together accurately and record the mass; dividing by five gives the mean mass of one tablet.
  • Grind the tablets to a fine powder in a mortar and pestle, adding a little dilute sulfuric acid.
  • Transfer the paste to a beaker with dilute sulfuric acid and deionised water, rinsing the mortar and pestle into the beaker, and stir to dissolve.
  • Transfer the solution, including any insoluble material, through a funnel into a 250 cm³ volumetric flask, rinsing the beaker, glass rod and funnel into the flask with deionised water.
  • Make up to the mark with deionised water, with the bottom of the meniscus on the mark at eye level and the last drops added with a dropper; stopper and invert about 20 times.
  • Diagram mortar and pestle holding the tablet powder, labelled with the pestle and the mortar bowl.
  • Diagram 250 cm³ volumetric flask with a funnel in its neck, labelled with the graduation mark.
  • Diagram beaker with a glass rod stirring the solution, labelled with the glass rod.

Titration of the tablet solution

  • Rinse the pipette with deionised water and then with the tablet solution; pipette 25.0 cm³ into a conical flask.
  • Add about 20 cm³ of dilute sulfuric acid (an excess) to the flask.
  • Rinse the burette with deionised water and then with the standard KMnO₄ solution; fill it and read the top of the meniscus.
  • Titrate, swirling, until one drop gives a permanent pale pink colour; no indicator is added.
  • Do a rough titration, then accurate titrations until two agree within 0.1 cm³; titrate soon after making the solution.
  • Diagram burette of purple KMnO₄ above a conical flask of tablet solution on a white tile, labelled with the burette tap and the top of the meniscus.

Why each choice is made

  • Dilute sulfuric acid is used to dissolve the tablets, stopping Fe²⁺ being oxidised to Fe³⁺ by dissolved oxygen; this would make the result too low, because Fe³⁺ does not react with MnO₄⁻.
  • More dilute sulfuric acid is added before each titration to supply the H⁺ ions needed for MnO₄⁻ to be reduced to Mn²⁺; with too little acid, brown MnO₂ forms and the 1 : 5 ratio no longer holds.
  • Several tablets are used: the result is an average over tablets that vary slightly in mass and iron content, a larger mass gives a smaller percentage error in weighing, and the solution is concentrated enough to give a reasonable titre.
  • Grinding increases the surface area so that the tablets dissolve fully and all the iron(II) is extracted.
  • The solution may be cloudy from the insoluble coating and binder (filler); this does not affect the result, because those substances do not react with the permanganate.
  • A volumetric flask and pipette are used because the 25.0 cm³ portion must be exactly one-tenth of the total.
  • No indicator is needed because KMnO₄ is self-indicating: the first excess drop colours the solution pink.

Sample calculation (sample data)

The steps convert the titre into the mass of iron in one tablet, then into a percentage of the tablet's mass.

  • Data: five tablets have a total mass of 1.80 g, a mean of 0.360 g per tablet; 25.0 cm³ portions of the 250 cm³ tablet solution need a mean titre of 11.6 cm³ of 0.0100 mol L⁻¹ KMnO₄.
  • Moles MnO₄⁻ = 0.0100 mol L⁻¹ × 0.0116 L = 1.16 × 10⁻⁴ mol.
  • Moles Fe²⁺ in 25.0 cm³ = 5 × 1.16 × 10⁻⁴ mol = 5.80 × 10⁻⁴ mol.
  • Moles Fe²⁺ in 250 cm³ (five tablets) = 5.80 × 10⁻⁴ mol × 10 = 5.80 × 10⁻³ mol; per tablet = 5.80 × 10⁻³ mol ÷ 5 = 1.16 × 10⁻³ mol.
  • Mass of iron per tablet = 1.16 × 10⁻³ mol × 56 g mol⁻¹ = 0.06496 g = 65.0 mg.
  • Percentage of iron by mass = 0.06496 g ÷ 0.360 g × 100 = 18.0%.
  • If the label gives the iron(II) sulfate content instead: mass of FeSO₄ per tablet = 1.16 × 10⁻³ mol × 152 g mol⁻¹ = 0.176 g = 176 mg; iron is 56 ÷ 152 = 36.8% of the mass of FeSO₄.
  • Conclusion: compare the result with the label value, calculate the percentage difference, and comment on whether the hypothesis is supported.

Safety

  • Wear goggles: dilute sulfuric acid is an irritant, and KMnO₄ is an oxidising agent that stains skin and clothes.
  • Iron tablets are dangerous if swallowed by young children: keep them secure and do not eat them in the laboratory.

Sources of error

  • Result too low: Fe²⁺ is oxidised to Fe³⁺ by air before titration, because the solution was not acidified or was left standing too long.
  • Result too low: tablet material is lost while grinding or transferring.
  • Result too high: overshooting the end point, taking a deep purple colour instead of the first permanent pale pink.
  • Result too high: tablets that also contain vitamin C or another reducing agent, which also reacts with MnO₄⁻.
  • Other error: too little acid gives brown MnO₂ and an unclear end point.
  • Other error: KMnO₄ that has partly decomposed since it was standardised.
  • Other error: a burette or pipette not rinsed with its own solution, as described in “Acid–base titrations”.

Key terms

Redox titration
A titration in which an oxidising agent reacts with a reducing agent of known concentration, or the reverse, with the mole ratio taken from the balanced redox equation.
Self-indicating
Describes a titration in which one reagent is intensely coloured enough to show the end point without an added indicator, as with potassium manganate(VII).
Autocatalysis
A reaction in which one of its products acts as a catalyst, as Mn²⁺ does in the reaction of MnO₄⁻ with Fe²⁺.
Double salt
A salt containing two simple salts crystallised together in a fixed ratio in one crystal, such as ammonium iron(II) sulfate.
Efflorescent
Describes a hydrated crystal that loses some of its water of crystallisation to the air on standing.
Hygroscopic
Describes a substance that absorbs water vapour from the air without dissolving in it.
Deliquescent
Describes a substance that absorbs enough water from the air to dissolve in it and form a solution.
Tri-iodide ion
The ion I₃⁻, formed when iodine reacts with iodide ions, which makes iodine soluble in water.
Starch indicator
A starch solution that forms a blue-black complex with iodine and is added near the end point of an iodine–thiosulfate titration.
Tetrathionate ion
The ion S₄O₆²⁻ formed when thiosulfate is oxidised by iodine.
Elemental iron
Iron in its free metallic form, Fe, as opposed to iron combined in a compound such as iron(II) sulfate.
Percentage by mass
The mass of an element in a sample divided by the mass of the sample, multiplied by 100.
Iron(II) sulfate
The salt FeSO₄, which contains iron in the +2 oxidation state and is commonly used in iron tablets.
Iron-deficiency anaemia
A condition in which the blood has too little haemoglobin because the body lacks iron.
Mean mass
The average mass of one tablet, found by weighing several tablets together and dividing by their number.
Scale factor
The total volume divided by the volume titrated, used to scale the moles in the portion up to the whole sample.
Volumetric flask
A flask that holds one fixed volume, such as 250 cm³, when filled to its mark.
Hypothesis
A testable prediction about the result that the investigation is designed to support or reject.

Practice questions

  1. Describe how a solution of potassium manganate(VII) is standardised using ammonium iron(II) sulfate. In your answer explain (i) why dilute sulfuric acid is used, (ii) how the end point is detected, (iii) what would be seen if too little acid were added.

    12 marks
  2. Explain why starch indicator is added only when the solution is pale yellow in an iodine–thiosulfate titration, and state the colour change at the end point. Why is potassium iodide used when making up an iodine solution?

    9 marks

Model answers, marking and 6 practice questions for this section are in the app. See the answers

Now drill Volumetric Analysis: Oxidation-Reduction.

Reading is step one. In the app, Volumetric Analysis: Oxidation-Reduction becomes 18 flashcards and 8 past exam questions marked the way the examiner marks them, with progress saved as you go. Free for Leaving Cert Chemistry students.