Leaving Cert Chemistry · pH and IndicatorsSelf-ionisation of water and pH

10 sections · 15 key terms · Syllabus 3.4.5, 3.4.6

Self-ionisation of water

Pure water contains a very small number of ions, produced when water molecules transfer protons to each other.

  • Pure water conducts electricity very slightly, so it must contain a small number of ions.
  • These ions come from the self-ionisation (auto-ionisation) of water, in which one water molecule donates a proton to another; this is a Brønsted–Lowry acid–base reaction: H₂O(l) + H₂O(l) ⇌ H₃O⁺(aq) + OH⁻(aq).
  • In simplified form: H₂O(l) ⇌ H⁺(aq) + OH⁻(aq).
  • The equilibrium lies very far to the left: at 25 °C only about 2 in every 1000 million (1.8 × 10⁻⁹) water molecules are ionised at any moment.
  • In pure water each ionisation gives one H₃O⁺ and one OH⁻, so [H₃O⁺] = [OH⁻].
  • A solution is neutral when [H⁺] = [OH⁻], acidic when [H⁺] > [OH⁻], and basic (alkaline) when [H⁺] < [OH⁻]; even acidic solutions contain some OH⁻ and basic solutions contain some H⁺.

Deducing Kw (Higher Level only)

  • Step 1: Write the equilibrium constant for H₂O ⇌ H⁺ + OH⁻: Kc = [H⁺][OH⁻] ÷ [H₂O].
  • Step 2: So little water ionises that [H₂O] is effectively constant: 1000 g of water per litre ÷ 18 g mol⁻¹ = 55.6 mol L⁻¹.
  • Step 3: Combine the two constants: Kc × [H₂O] = [H⁺][OH⁻]. This new constant is the ionic product of water, Kw.
  • Definition: Kw = [H₃O⁺][OH⁻], or in simplified form Kw = [H⁺][OH⁻]; it is the product of the hydrogen ion and hydroxide ion concentrations.
  • At 25 °C, Kw = 1.0 × 10⁻¹⁴ (units mol² L⁻², often omitted).

Using Kw (Higher Level only)

  • Pure water at 25 °C has [H⁺] = [OH⁻], so [H⁺]² = 1.0 × 10⁻¹⁴.
  • Therefore [H⁺] = √(1.0 × 10⁻¹⁴) = 1.0 × 10⁻⁷ mol L⁻¹.
  • So pH = −log₁₀(1.0 × 10⁻⁷) = 7.0, which is why pH 7 is neutral at 25 °C.
  • Kw applies to every dilute aqueous solution, not just pure water: if [H⁺] rises, [OH⁻] falls so that the product stays 1.0 × 10⁻¹⁴ at 25 °C.
  • Example: a solution with [H⁺] = 1.0 × 10⁻² mol L⁻¹ (pH 2) has [OH⁻] = 1.0 × 10⁻¹⁴ ÷ 1.0 × 10⁻² = 1.0 × 10⁻¹² mol L⁻¹.
  • Taking −log₁₀ of Kw = [H⁺][OH⁻] gives pH + pOH = 14 at 25 °C, where pOH = −log₁₀[OH⁻]; this is used for bases in “pH calculations”.

Temperature dependence of Kw (Higher Level only)

  • Self-ionisation is endothermic in the forward direction (ΔH about +56 kJ mol⁻¹); it is the reverse of neutralisation, H⁺ + OH⁻ → H₂O, which is exothermic.
  • By Le Châtelier's principle, raising the temperature shifts the equilibrium to the right, the endothermic direction, producing more H⁺ and OH⁻, so Kw increases; cooling decreases Kw.
  • Like every equilibrium constant, Kw changes only with temperature; that is why Kw values are quoted with a temperature.
  • Kw at 0 °C is 1.1 × 10⁻¹⁵, giving a neutral pH of 7.48.
  • Kw at 25 °C is 1.0 × 10⁻¹⁴, giving a neutral pH of 7.00.
  • Kw at 50 °C is 5.5 × 10⁻¹⁴, giving a neutral pH of 6.63.
  • Kw at 100 °C is 5.1 × 10⁻¹³, giving a neutral pH of 6.15.
  • Hot pure water has a pH below 7 but is still neutral, because [H⁺] and [OH⁻] increase equally and stay equal; neutral means [H⁺] = [OH⁻], not pH = 7.
  • The neutral pH is therefore lower at higher temperatures and higher at lower temperatures.

The pH scale

  • pH is defined as pH = −log₁₀[H⁺], where [H⁺] is the concentration of hydrogen (hydronium) ions in mol L⁻¹.
  • The scale was introduced by the Danish chemist Søren Sørensen in 1909, while working at the Carlsberg Laboratory in Copenhagen, as a convenient way to express very small [H⁺] values.
  • At 25 °C, pH below 7 is acidic, pH 7 is neutral and pH above 7 is basic (alkaline); the lower the pH, the more acidic the solution.
  • Where [H⁺] = 10⁻ˣ mol L⁻¹, the pH is x: for example, [H⁺] = 10⁻⁴ mol L⁻¹ gives pH 4.
  • The scale is logarithmic: a change of 1 pH unit is a tenfold change in [H⁺]; a solution of pH 3 has 10 times the [H⁺] of one of pH 4 and 100 times that of one of pH 5.
  • Stomach acid has a pH of about 1–2; lemon juice about 2–3; vinegar about 3.
  • Pure water has pH 7, and blood 7.35–7.45.
  • Baking soda solution has a pH of about 8–9; milk of magnesia about 10.5.
  • Household ammonia has a pH of about 11–12; oven cleaner (sodium hydroxide) about 13–14.

Converting between pH and [H⁺]

  • From [H⁺] to pH: pH = −log₁₀[H⁺]. For example, [H⁺] = 3.5 × 10⁻⁴ mol L⁻¹ gives pH = −log₁₀(3.5 × 10⁻⁴) = 3.46.
  • For example, [H⁺] = 7.1 × 10⁻⁷ mol L⁻¹ gives pH = 6.15, which is slightly acidic at 25 °C.
  • From pH to [H⁺]: [H⁺] = 10⁻ᵖᴴ, the antilog of −pH. For example, pH 3.7 gives [H⁺] = 10⁻³·⁷ = 2.00 × 10⁻⁴ mol L⁻¹.
  • For example, pH 8.6 gives [H⁺] = 10⁻⁸·⁶ = 2.51 × 10⁻⁹ mol L⁻¹.
  • On a calculator, use the log key with a minus sign to find pH, and the 10ˣ key (or inverse log) with −pH to find [H⁺]; give pH to two decimal places unless the question asks otherwise.

Limitations of the pH scale

  • It is normally used only between 0 and 14; very concentrated acids and alkalis go outside this range, where pH is not a convenient measure.
  • For example, 2.0 M HCl has pH −log₁₀(2.0) = −0.30.
  • It is reliable only for dilute solutions; in concentrated solutions (above about 1 mol L⁻¹) the ions interact and the measured pH no longer matches −log₁₀ of the concentration.
  • It applies only to aqueous solutions.
  • pH 7 is neutral only at 25 °C (see “Self-ionisation of water”).

Measuring pH

  • Universal indicator (solution or paper): add a few drops to the solution, or dip in a strip of paper, and compare the colour with the colour chart; it gives the pH only approximately, to about the nearest whole unit.
  • The colours of universal indicator are given in “Categorising acids and bases”.
  • A pH meter (or pH sensor with a data-logger) uses a glass electrode probe that responds to [H⁺] and gives a digital reading, usually to 0.01 pH units.
  • Calibrate the meter before use: place the rinsed probe in buffer solutions of known pH (e.g. pH 4.00 and 7.00, or 7.00 and 10.00) and set the meter to read these values.
  • A buffer solution resists a change in pH when small amounts of acid or base are added, so its pH is reliably known.
  • Rinse the probe with deionised water between solutions and blot it dry gently, so one solution does not contaminate the next; store the bulb wet, as directed.
  • A pH meter gives a precise numerical value (e.g. 4.72) rather than an estimate.
  • A pH meter needs no judgement of colour, which varies from person to person and with lighting.
  • A pH meter works in coloured or cloudy solutions, where an indicator colour cannot be seen, and can record pH continuously (as in “pH titration curves”).
  • Single indicators such as litmus, methyl orange and phenolphthalein show only whether the pH is above or below their colour-change range, not a pH value.

Practical: measuring the pH of everyday substances

The aim is to compare the pH of several substances by two methods and check that they agree.

  • Aim: to measure and compare the pH of everyday substances, e.g. vinegar, lemon juice, a soft drink, tap water, toothpaste or an antacid tablet mixed with deionised water, and baking soda solution.
  • Step 1: Put about 20 cm³ of each sample in a clean, labelled beaker.
  • Step 2: Test each sample with universal indicator paper and record the pH from the colour chart.
  • Step 3: Measure each sample with a calibrated pH meter, rinsing the probe between samples.
  • Step 4: Repeat each reading.
  • Use deionised water to dissolve or mix solids, because tap water may contain dissolved substances that change the pH.
  • Results: record both sets of readings in a table and rank the substances from most acidic to most basic.
  • The meter readings are more precise, and the two methods should agree to about one unit.
  • Safety: wear goggles; treat oven cleaner and other strong alkalis as corrosive (use gloves, small volumes, or omit them); do not taste any sample.
  • Sources of error: a probe that is not calibrated or not rinsed; a temperature different from the calibration temperature; misjudging indicator colours.
  • Diagram a pH probe in a beaker of sample, connected to a meter (or data-logger) showing a digital reading.
  • Diagram universal indicator paper beside its colour chart.

Factors that affect pH (Higher Level only)

The pH depends on the [H⁺] in the solution, which depends on how far the acid dissociates and on its concentration.

  • Tendency to dissociate: at the same concentration, a strong acid has a lower pH than a weak acid.
  • For example, 0.10 M HCl has pH 1.00, but 0.10 M ethanoic acid (Ka 1.8 × 10⁻⁵) has pH 2.87, because the weak acid is only about 1% dissociated.
  • Concentration: diluting an acid lowers [H⁺] and raises the pH.
  • Diluting a strong acid ten times raises its pH by 1: 0.10 M HCl has pH 1.00 and 0.010 M HCl has pH 2.00.
  • Diluting a weak acid ten times raises its pH by only about 0.5: 0.10 M ethanoic acid has pH 2.87 and 0.010 M has pH 3.37.
  • This is because [H⁺] depends on the square root of the concentration, and dilution makes a weak acid dissociate a larger fraction (see “Degree of dissociation”).
  • Temperature: Kw increases with temperature, so the pH of pure water and of neutral solutions falls, to 6.15 at 100 °C (see “Self-ionisation of water”).
  • Ka and Kb also change with temperature, so the pH of weak acids and bases changes; Ka and Kb values are quoted at 25 °C.
  • For a base, the pH also changes with temperature at fixed [OH⁻], because [H⁺] = Kw ÷ [OH⁻] and Kw changes.
  • For example, 0.010 M NaOH has pH 12.00 at 25 °C but about 11.3 at 50 °C.
  • pH measures acidity (the [H⁺] in the solution), not the strength of the acid: a very dilute strong acid can have a higher pH than a concentrated weak acid.
  • For example, 1.0 × 10⁻⁵ M HCl has pH 5.00, while 1.0 M ethanoic acid has pH 2.37.

Key terms

Self-ionisation
The reaction in which one water molecule transfers a proton to another, producing a very small amount of H₃O⁺ and OH⁻ ions.
Hydronium ion
The H₃O⁺ ion formed when a water molecule accepts a proton; it is often written simply as H⁺(aq) in equations.
Ionic product of water (Kw)
The constant Kw = [H⁺][OH⁻] for water and dilute aqueous solutions, equal to 1.0 × 10⁻¹⁴ at 25 °C.
Neutral solution
A solution in which [H⁺] = [OH⁻].
Acidic solution
A solution in which [H⁺] is greater than [OH⁻].
Basic solution
A solution in which [H⁺] is less than [OH⁻]; also called alkaline.
Endothermic reaction
A reaction that takes in heat energy from its surroundings.
pH
The negative logarithm (base 10) of the hydrogen ion concentration in mol L⁻¹, pH = −log₁₀[H⁺].
Logarithmic scale
A scale on which each unit change represents a tenfold change in the quantity measured, as in the pH scale.
Universal indicator
A mixture of indicators that changes through a range of colours across the pH scale, read against a colour chart.
pH meter
An instrument with a glass electrode probe that gives a digital pH reading, usually to 0.01 pH units.
Buffer solution
A solution that resists a change in pH when small amounts of acid or base are added, used to calibrate a pH meter.
Calibrate
To set a pH meter so that it reads the known pH values of buffer solutions.
Deionised water
Water from which dissolved ions have been removed, so that it does not change the pH of the substance mixed with it.
Dissociation
The splitting of a molecule into ions when it dissolves in water.

Practice questions

  1. Write an equation for the self-ionisation of water and explain why pure water is described as neutral.

    6 marks
  2. Define the ionic product of water, Kw. Kw at 25 °C is 1.0 × 10⁻¹⁴. Show that the pH of pure water at 25 °C is 7.0, and calculate [OH⁻] in a solution with [H⁺] = 1.0 × 10⁻³ mol L⁻¹.

    9 marks

Model answers, marking and 6 practice questions for this section are in the app. See the answers

Now drill pH and Indicators.

Reading is step one. In the app, pH and Indicators becomes 31 flashcards and 14 past exam questions marked the way the examiner marks them, with progress saved as you go. Free for Leaving Cert Chemistry students.