Leaving Cert Chemistry · pH and IndicatorsSelf-ionisation of water and pH
Self-ionisation of water
Pure water contains a very small number of ions, produced when water molecules transfer protons to each other.
- Pure water conducts electricity very slightly, so it must contain a small number of ions.
- These ions come from the self-ionisation (auto-ionisation) of water, in which one water molecule donates a proton to another; this is a Brønsted–Lowry acid–base reaction: H₂O(l) + H₂O(l) ⇌ H₃O⁺(aq) + OH⁻(aq).
- In simplified form: H₂O(l) ⇌ H⁺(aq) + OH⁻(aq).
- The equilibrium lies very far to the left: at 25 °C only about 2 in every 1000 million (1.8 × 10⁻⁹) water molecules are ionised at any moment.
- In pure water each ionisation gives one H₃O⁺ and one OH⁻, so [H₃O⁺] = [OH⁻].
- A solution is neutral when [H⁺] = [OH⁻], acidic when [H⁺] > [OH⁻], and basic (alkaline) when [H⁺] < [OH⁻]; even acidic solutions contain some OH⁻ and basic solutions contain some H⁺.
Deducing Kw (Higher Level only)
- Step 1: Write the equilibrium constant for H₂O ⇌ H⁺ + OH⁻: Kc = [H⁺][OH⁻] ÷ [H₂O].
- Step 2: So little water ionises that [H₂O] is effectively constant: 1000 g of water per litre ÷ 18 g mol⁻¹ = 55.6 mol L⁻¹.
- Step 3: Combine the two constants: Kc × [H₂O] = [H⁺][OH⁻]. This new constant is the ionic product of water, Kw.
- Definition: Kw = [H₃O⁺][OH⁻], or in simplified form Kw = [H⁺][OH⁻]; it is the product of the hydrogen ion and hydroxide ion concentrations.
- At 25 °C, Kw = 1.0 × 10⁻¹⁴ (units mol² L⁻², often omitted).
Using Kw (Higher Level only)
- Pure water at 25 °C has [H⁺] = [OH⁻], so [H⁺]² = 1.0 × 10⁻¹⁴.
- Therefore [H⁺] = √(1.0 × 10⁻¹⁴) = 1.0 × 10⁻⁷ mol L⁻¹.
- So pH = −log₁₀(1.0 × 10⁻⁷) = 7.0, which is why pH 7 is neutral at 25 °C.
- Kw applies to every dilute aqueous solution, not just pure water: if [H⁺] rises, [OH⁻] falls so that the product stays 1.0 × 10⁻¹⁴ at 25 °C.
- Example: a solution with [H⁺] = 1.0 × 10⁻² mol L⁻¹ (pH 2) has [OH⁻] = 1.0 × 10⁻¹⁴ ÷ 1.0 × 10⁻² = 1.0 × 10⁻¹² mol L⁻¹.
- Taking −log₁₀ of Kw = [H⁺][OH⁻] gives pH + pOH = 14 at 25 °C, where pOH = −log₁₀[OH⁻]; this is used for bases in “pH calculations”.
Temperature dependence of Kw (Higher Level only)
- Self-ionisation is endothermic in the forward direction (ΔH about +56 kJ mol⁻¹); it is the reverse of neutralisation, H⁺ + OH⁻ → H₂O, which is exothermic.
- By Le Châtelier's principle, raising the temperature shifts the equilibrium to the right, the endothermic direction, producing more H⁺ and OH⁻, so Kw increases; cooling decreases Kw.
- Like every equilibrium constant, Kw changes only with temperature; that is why Kw values are quoted with a temperature.
- Kw at 0 °C is 1.1 × 10⁻¹⁵, giving a neutral pH of 7.48.
- Kw at 25 °C is 1.0 × 10⁻¹⁴, giving a neutral pH of 7.00.
- Kw at 50 °C is 5.5 × 10⁻¹⁴, giving a neutral pH of 6.63.
- Kw at 100 °C is 5.1 × 10⁻¹³, giving a neutral pH of 6.15.
- Hot pure water has a pH below 7 but is still neutral, because [H⁺] and [OH⁻] increase equally and stay equal; neutral means [H⁺] = [OH⁻], not pH = 7.
- The neutral pH is therefore lower at higher temperatures and higher at lower temperatures.
The pH scale
- pH is defined as pH = −log₁₀[H⁺], where [H⁺] is the concentration of hydrogen (hydronium) ions in mol L⁻¹.
- The scale was introduced by the Danish chemist Søren Sørensen in 1909, while working at the Carlsberg Laboratory in Copenhagen, as a convenient way to express very small [H⁺] values.
- At 25 °C, pH below 7 is acidic, pH 7 is neutral and pH above 7 is basic (alkaline); the lower the pH, the more acidic the solution.
- Where [H⁺] = 10⁻ˣ mol L⁻¹, the pH is x: for example, [H⁺] = 10⁻⁴ mol L⁻¹ gives pH 4.
- The scale is logarithmic: a change of 1 pH unit is a tenfold change in [H⁺]; a solution of pH 3 has 10 times the [H⁺] of one of pH 4 and 100 times that of one of pH 5.
- Stomach acid has a pH of about 1–2; lemon juice about 2–3; vinegar about 3.
- Pure water has pH 7, and blood 7.35–7.45.
- Baking soda solution has a pH of about 8–9; milk of magnesia about 10.5.
- Household ammonia has a pH of about 11–12; oven cleaner (sodium hydroxide) about 13–14.
Converting between pH and [H⁺]
- From [H⁺] to pH: pH = −log₁₀[H⁺]. For example, [H⁺] = 3.5 × 10⁻⁴ mol L⁻¹ gives pH = −log₁₀(3.5 × 10⁻⁴) = 3.46.
- For example, [H⁺] = 7.1 × 10⁻⁷ mol L⁻¹ gives pH = 6.15, which is slightly acidic at 25 °C.
- From pH to [H⁺]: [H⁺] = 10⁻ᵖᴴ, the antilog of −pH. For example, pH 3.7 gives [H⁺] = 10⁻³·⁷ = 2.00 × 10⁻⁴ mol L⁻¹.
- For example, pH 8.6 gives [H⁺] = 10⁻⁸·⁶ = 2.51 × 10⁻⁹ mol L⁻¹.
- On a calculator, use the log key with a minus sign to find pH, and the 10ˣ key (or inverse log) with −pH to find [H⁺]; give pH to two decimal places unless the question asks otherwise.
Limitations of the pH scale
- It is normally used only between 0 and 14; very concentrated acids and alkalis go outside this range, where pH is not a convenient measure.
- For example, 2.0 M HCl has pH −log₁₀(2.0) = −0.30.
- It is reliable only for dilute solutions; in concentrated solutions (above about 1 mol L⁻¹) the ions interact and the measured pH no longer matches −log₁₀ of the concentration.
- It applies only to aqueous solutions.
- pH 7 is neutral only at 25 °C (see “Self-ionisation of water”).
Measuring pH
- Universal indicator (solution or paper): add a few drops to the solution, or dip in a strip of paper, and compare the colour with the colour chart; it gives the pH only approximately, to about the nearest whole unit.
- The colours of universal indicator are given in “Categorising acids and bases”.
- A pH meter (or pH sensor with a data-logger) uses a glass electrode probe that responds to [H⁺] and gives a digital reading, usually to 0.01 pH units.
- Calibrate the meter before use: place the rinsed probe in buffer solutions of known pH (e.g. pH 4.00 and 7.00, or 7.00 and 10.00) and set the meter to read these values.
- A buffer solution resists a change in pH when small amounts of acid or base are added, so its pH is reliably known.
- Rinse the probe with deionised water between solutions and blot it dry gently, so one solution does not contaminate the next; store the bulb wet, as directed.
- A pH meter gives a precise numerical value (e.g. 4.72) rather than an estimate.
- A pH meter needs no judgement of colour, which varies from person to person and with lighting.
- A pH meter works in coloured or cloudy solutions, where an indicator colour cannot be seen, and can record pH continuously (as in “pH titration curves”).
- Single indicators such as litmus, methyl orange and phenolphthalein show only whether the pH is above or below their colour-change range, not a pH value.
Practical: measuring the pH of everyday substances
The aim is to compare the pH of several substances by two methods and check that they agree.
- Aim: to measure and compare the pH of everyday substances, e.g. vinegar, lemon juice, a soft drink, tap water, toothpaste or an antacid tablet mixed with deionised water, and baking soda solution.
- Step 1: Put about 20 cm³ of each sample in a clean, labelled beaker.
- Step 2: Test each sample with universal indicator paper and record the pH from the colour chart.
- Step 3: Measure each sample with a calibrated pH meter, rinsing the probe between samples.
- Step 4: Repeat each reading.
- Use deionised water to dissolve or mix solids, because tap water may contain dissolved substances that change the pH.
- Results: record both sets of readings in a table and rank the substances from most acidic to most basic.
- The meter readings are more precise, and the two methods should agree to about one unit.
- Safety: wear goggles; treat oven cleaner and other strong alkalis as corrosive (use gloves, small volumes, or omit them); do not taste any sample.
- Sources of error: a probe that is not calibrated or not rinsed; a temperature different from the calibration temperature; misjudging indicator colours.
- Diagram a pH probe in a beaker of sample, connected to a meter (or data-logger) showing a digital reading.
- Diagram universal indicator paper beside its colour chart.
Factors that affect pH (Higher Level only)
The pH depends on the [H⁺] in the solution, which depends on how far the acid dissociates and on its concentration.
- Tendency to dissociate: at the same concentration, a strong acid has a lower pH than a weak acid.
- For example, 0.10 M HCl has pH 1.00, but 0.10 M ethanoic acid (Ka 1.8 × 10⁻⁵) has pH 2.87, because the weak acid is only about 1% dissociated.
- Concentration: diluting an acid lowers [H⁺] and raises the pH.
- Diluting a strong acid ten times raises its pH by 1: 0.10 M HCl has pH 1.00 and 0.010 M HCl has pH 2.00.
- Diluting a weak acid ten times raises its pH by only about 0.5: 0.10 M ethanoic acid has pH 2.87 and 0.010 M has pH 3.37.
- This is because [H⁺] depends on the square root of the concentration, and dilution makes a weak acid dissociate a larger fraction (see “Degree of dissociation”).
- Temperature: Kw increases with temperature, so the pH of pure water and of neutral solutions falls, to 6.15 at 100 °C (see “Self-ionisation of water”).
- Ka and Kb also change with temperature, so the pH of weak acids and bases changes; Ka and Kb values are quoted at 25 °C.
- For a base, the pH also changes with temperature at fixed [OH⁻], because [H⁺] = Kw ÷ [OH⁻] and Kw changes.
- For example, 0.010 M NaOH has pH 12.00 at 25 °C but about 11.3 at 50 °C.
- pH measures acidity (the [H⁺] in the solution), not the strength of the acid: a very dilute strong acid can have a higher pH than a concentrated weak acid.
- For example, 1.0 × 10⁻⁵ M HCl has pH 5.00, while 1.0 M ethanoic acid has pH 2.37.
Key terms
- Self-ionisation
- The reaction in which one water molecule transfers a proton to another, producing a very small amount of H₃O⁺ and OH⁻ ions.
- Hydronium ion
- The H₃O⁺ ion formed when a water molecule accepts a proton; it is often written simply as H⁺(aq) in equations.
- Ionic product of water (Kw)
- The constant Kw = [H⁺][OH⁻] for water and dilute aqueous solutions, equal to 1.0 × 10⁻¹⁴ at 25 °C.
- Neutral solution
- A solution in which [H⁺] = [OH⁻].
- Acidic solution
- A solution in which [H⁺] is greater than [OH⁻].
- Basic solution
- A solution in which [H⁺] is less than [OH⁻]; also called alkaline.
- Endothermic reaction
- A reaction that takes in heat energy from its surroundings.
- pH
- The negative logarithm (base 10) of the hydrogen ion concentration in mol L⁻¹, pH = −log₁₀[H⁺].
- Logarithmic scale
- A scale on which each unit change represents a tenfold change in the quantity measured, as in the pH scale.
- Universal indicator
- A mixture of indicators that changes through a range of colours across the pH scale, read against a colour chart.
- pH meter
- An instrument with a glass electrode probe that gives a digital pH reading, usually to 0.01 pH units.
- Buffer solution
- A solution that resists a change in pH when small amounts of acid or base are added, used to calibrate a pH meter.
- Calibrate
- To set a pH meter so that it reads the known pH values of buffer solutions.
- Deionised water
- Water from which dissolved ions have been removed, so that it does not change the pH of the substance mixed with it.
- Dissociation
- The splitting of a molecule into ions when it dissolves in water.
Practice questions
Write an equation for the self-ionisation of water and explain why pure water is described as neutral.
6 marksDefine the ionic product of water, Kw. Kw at 25 °C is 1.0 × 10⁻¹⁴. Show that the pH of pure water at 25 °C is 7.0, and calculate [OH⁻] in a solution with [H⁺] = 1.0 × 10⁻³ mol L⁻¹.
9 marks
Model answers, marking and 6 practice questions for this section are in the app. See the answers